Cecilware Food Warmer FW 25 User Manual

ELECTRIC COUNTER TOP  
WARMER  
OPERATION MANUAL  
FW-25  
FW-25WT  
FW-25 Shown  
CECILWARE CORPORATION  
43-05 20th AVENUE, LONG ISLAND CITY, NEW YORK 11105-1295 ■  
718-932-1414  
FAX 718-932-7860  
NN56A 5/05  
 
Introduction  
Congratulations on the purchase of your Cecilware Counter Top Warmer. Please take a few moments  
to carefully read through this manual to ensure the machine is operated and maintained properly. This  
will enable the best possible performance from this product for many years.  
Cecilware will not accept liability for the following if:  
* The instructions in this manual have not been followed correctly.  
* Non-authorized personnel have tampered with the machine.  
* Non-original spare parts are used.  
* The machine has not been handled and cleaned correctly.  
Packaging  
Cecilware prides itself on quality and service, ensuring that at the time of packing all products are  
supplied fully functional and free of damage.  
Provided in this package are the following:  
* Warmer  
* Divider Bar  
* Manual  
Should you find any damage as a result of freight, please contact your Cecilware dealer immediately.  
Installation  
Remove the Counter Top Warmer from the packaging. Be certain all protective plastics and residues  
are thoroughly cleaned from its surface.  
Place the Warmer on a firm level surface clear from all combustible materials.  
Supply the appropriate power--(See specifications on page 6). Plug in and turn the power on.  
Operation  
Fill the Warmer with water to the indicated level. Do not overfill; under no circumstances, should the  
food pans float. If this occurs, remove excess water. It is recommended to use fresh clean water for  
each use.  
To switch on, simply turn the temperature dial clockwise to the desired setting. The red light will glow  
to indicate the unit is on. To turn off, simply turn the temperature dial counter clockwise to the 0  
setting. It is recommended that the thermostat be set to the maximum heat of 195º F (1 full turn  
clockwise) for pre-heating the warmer. An operating setting of 168º F should be sufficient once the  
unit is pre-heated.  
NOTE: Do not lift, move or carry the warmer when on; nor should you move the unit when it contains  
food or water.  
2
 
Cleaning, Care and Maintenance  
Switch off the power and disconnect from the source. Ensure that the unit is always switched off and  
unplugged while cleaning, maintaining or moving.  
The Warmer should be cleaned after each day’s operation; however, additional cleaning may be  
required depending on daily use. Before cleaning, allow the warmer to cool down  
Empty the water basin, and clean after each use. Pans and lids can be removed to be cleaned. The  
Warmer can be wiped down with a damp cloth. Do not immerse the Warmer in water or use hose to  
clean.  
Warm soapy water is recommended for cleaning. Cleaning agents may cause damage when used for a  
prolonged period on stainless steel.  
Safety  
A Cecilware Recommended Qualified Service Technician should carry out repairs if necessary.  
*Switch off power to and disconnect from the outlet when cleaning, maintaining or moving.  
To avoid over heating or damage to the element, this unit has been installed with a Hi Limit. If the Hi  
Limit is tripped, please call a Recommended Qualified Service Technician to check over the warmer,  
repair if needed and reset the Hi Limit.  
Trouble Shooting  
If your Cecilware Warmer does not operate, please check the following before placing a service call.  
Electric Counter  
FW-25, FW-25-WT  
Top Warmer  
Problem  
Cause  
Remedy  
1. Mains power supply  
1. Check mains power supply  
2. Power switch has not been 2. Check the unit is correctly plugged in and  
turned on  
turned on  
3. Replace the fuse in the plug with correctly  
rated fuse  
3. Fuse in the plug has blown  
The unit is not  
working and the  
indicator light is not  
on  
4. On/off switch is faulty  
5. Plug and lead are damaged  
6. Internal wiring fault  
4. Call service agent or qualified technician  
5. Call service agent or qualified technician  
6. Call service agent or qualified technician  
7. This is a safety device that has disconnected  
the power: call a service agent or qualified  
technician  
7. Thermal  
activated  
cut-out  
has  
3
 
Problem  
Cause  
Remedy  
The unit is heating but the 1. The indicator bulb has 1. Replace the indicator light: call a  
indicator light is not on  
blown  
service agent or qualified technician  
1.Call service agent or qualified  
technician  
1.Faulty element(s)  
2. Ensure that the thermostat is set  
correctly, also ensure the dial is not  
spinning on the thermostat and giving the  
wrong reading  
Indicator light is on but the  
unit is not heating  
2.Operation of thermostat  
3.  
Call service agent or qualified  
3.Faulty thermostat  
1.No water in the pan  
2. Thermostat setting  
3. Faulty element(s)  
technician  
1. Fill the pan to the indicated level  
(between Min and Max)  
2. Ensure that the thermostat is set  
correctly, and the dial is not spinning  
Slow heat up  
3.  
Call service agent or qualified  
technician  
Please ensure:  
*There is correct power supply.  
*The machine is plugged in correctly and power is switched on.  
*The thermostat dial has been turned on.  
Note: All Cecilware products are tested prior to packing.  
Compliance  
Cecilware products have undergone strict product testing in order to comply with regulatory standards  
and specifications set by international, independent, and federal authorities.  
As testimony to such compliance, Cecilware products carry the following marks/symbols:  
4
 
Electrical Diagram  
Model: FW-25, FW-25WT  
120V  
hi-limit  
on/off  
switch  
thermostat  
pilot light  
heating  
element  
The above circuit diagram has been provided to assist qualified technicians. A Recommended Qualified  
Service Technician should carry out repairs if needed. Do not remove any components or service panels  
on this product.  
5
 
Explosion View  
FW-25  
1
2
3
14  
4
5
6
15  
7
13  
8
9
12  
11  
10  
FW-25WT  
1
2
3
14  
4
5
18  
17  
6
7
15  
13  
8
9
12  
11  
10  
6
 
Spare Parts List  
No.  
1
Description  
QTY  
1
Part NO  
08056  
08057  
NA  
WATER PAN  
2
HEATING ELEMENT - 120V, 1500W  
ELEMENT FIXING PLATE  
INSULATION  
1
3
1
4
1
NA  
5
INSULATION COVER  
PAN HOLDERS  
1
NA  
6
2
08058  
NA  
7
MAIN BODY  
1
8
BASE PLATE  
1
NA  
9
FEET  
4
08059  
08060  
08027  
08032  
08054  
08079  
08055  
08089  
08090  
08091  
10  
11  
12  
13  
14  
15  
16  
17  
18  
THERMOSTAT DIAL  
THERMOSTAT  
1
1
PILOT LIGHT  
1
ON/OFF SWITCH  
HI-LIMIT  
1
1
CORD & PLUG  
1
DRIP TAP  
1
FLEXIBLE HOSE CONNECTION  
STUFFING PLUG  
1
1
*NA = not available except by special order.  
Specifications  
DIMENSIONS (INCHS)  
MODEL  
VOLTAGE  
POWER  
W×D×H  
120V  
50/60 HZ  
FW-25  
1500W  
14 3/8×23 1/2×10 1/2”  
14 3/8×25 3/4×10 1/2”  
120V  
50/60 HZ  
FW-25WT  
1500W  
7
 
CECILWARE CORPORATION  
43-05 20th AVENUE, LONG ISLAND CITY, NEW YORK 11105-1295 ■  
718-932-1414  
FAX 718-932-7860  
8
 

Bissell Vacuum Cleaner 17G5 User Manual
Black Box Modem Fiber Optic Modem User Manual
Broan Fan QTX100HL User Manual
Broan Ventilation Hood PM390HS User Manual
Brother Saw MW 140BT User Manual
BUSH Flat Panel Television IDLCD1904HD User Manual
Cadco Can Opener EC 10 User Manual
Califone Digital Camera Pa 8 User Manual
Carson Optical TV Mount ED1928 User Manual
Casio Digital Camera EX S20U User Manual