Features and Benefits
Refrigerant System
• Environmentally friendly R410A refrigerant
• Copper tubing with enhanced fin coils
• External service gauge ports
Cabinet Construction
• Low profile, with compact footprint
• Insulation to minimize heat loss plus reduce
sound
• Baked on pre painted steel cabinet finish
• Easy service access
• Wire grill protection
• One piece “no leak” top design
Blower
• Insulated compartment to reduce sound
• High efficiency multispeed motor for wide
airflow range
Controls
• Integrated control with L.E.D. diagostics
• Defrost control board with field selectable
time intervals
• High and low refrigerant pressure switches
for system protection
Installation
Warranty
• 10 year limited parts and compressor
warranty. See limited warranty
document for details.
• Full perimeter base rail system for easy installation
• Horizontal or down discharge, duct covers provided
• Utility connections on “right side”
• Filter channels for 1" filter field provided
RHP13
Package Heat Pump
13
Blower Performance
CFM @ ext. Static Pressure in inches wc without filter, dry coil
Blower
Model
Tap
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
2
640
830
950
900
1060
650
460
800
910
870
1030
550
370
760
880
830
980
---
710
840
800
960
430
930
---
640
800
730
930
---
900
1010
970
---
600
750
690
910
---
860
980
---
570
700
640
860
---
820
960
920
960
---
980
1080
980
1080
---
990
1160
1090
1160
---
1290
1330
1290
1330
---
1380
1360
1380
1360
RHP13A24P
RHP13A30P
RHP13A36P
RHP13A42P
RHP13A48P
RHP13A60P
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
490
970
1030
1150
1110
1150
650
1240
1320
1240
1320
780
1450
1650
1510
1650
860
1650
1800
1650
1800
1000
1820
1950
1820
1950
1000
1110
1070
1110
590
1200
1260
1200
1260
690
1370
1570
1430
1570
760
1600
1750
1600
1750
900
1080
1040
1080
500
1150
1230
1150
1230
610
1280
1510
1380
1510
690
1550
1690
1550
1690
800
1050
1000
1050
430
1100
1200
1100
1200
540
1200
1440
1290
1440
640
1500
1630
1500
1630
750
950
980
---
1010
---
1060
1160
1060
1160
---
1120
1360
1220
1360
---
1440
1570
1440
1570
---
1630
1700
1630
1700
1020
1120
1020
1120
---
1060
1260
1150
1260
---
1370
1470
1370
1470
---
1530
1560
1530
1560
1790
1910
1790
1910
1730
1860
1730
1860
1670
1800
1670
1800
Taps 4 & 5 are used with Electric Heat. Refer to Heater Label on unit for
proper Heat Tap selection
Subtract .10 Duct Static for Downflow CFM
Heating Performance Extended Ratings
Outdoor Temp - DB/WB ºF
35/33
Btuh
0/0
17/15
Btuh
47/43
Btuh
62/56
Model
Btuh
kW
kW
kW
kW
Btuh
kW
RHP13A24P
RHP13A30P
RHP13A36P
RHP13A42P
RHP13A48P
RHP13A60P
10,100
10,700
15,900
19,600
23,900
25,200
1.71
2.03
2.53
2.92
3.57
4.30
13,000
16,000
20,200
22,400
26,800
34,000
1.73
2.04
2.58
2.99
3.74
15,400
21,100
24,900
26,600
29,300
41,200
1.71
2.14
2.66
3.20
3.73
4.32
21,600
27,000
33,600
39,000
44,000
54,000
1.80
2.26
2.82
3.36
3.91
4.78
26,200
32,700
40,200
46,800
52,900
64,800
1.87
2.33
2.93
3.48
4.08
5.03
4.34
- Page 3 -
RHP13
Package Heat Pump
13
Cooling Performance Extended Ratings
Outdoor Temp - DBºF
95°
Indoor
Temp
DB/WB
ºF
65°
S/T kW
82°
S/T kW
105°
115°
Model
Btuh
Btuh
Btuh
S/T kW
Btuh S/T kW Btuh S/T kW
85/72 28,100 0.59 1.60 26,500 0.62 1.89 25,300 0.65 2.10 23,700 0.68 2.33 21,800 0.71 2.31
80/67 26,500 0.67 1.59 25,000 0.70 1.85 23,000 0.74 2.09 21,400 0.76 2.31 19,100 0.81 2.30
75/63 25,000 0.71 1.58 22,600 0.74 1.87 20,700 0.76 2.08 19,100 0.81 2.30 17,100 0.85 2.29
75/57 23,100 1.00 1.56 21,600 1.00 1.84 20,500 1.00 2.05 18,800 1.00 2.27 16,900 1.00 2.25
85/72 33,700 0.61 1.97 31,900 0.64 2.30 30,500 0.67 2.56 28,200 0.70 2.84 25,900 0.73 2.82
80/67 32,100 0.68 1.96 29,900 0.72 2.27 28,000 0.75 2.55 25,700 0.79 2.81 22,500 0.84 2.79
75/63 30,200 0.72 1.95 27,400 0.76 2.28 25,200 0.79 2.53 22,600 0.84 2.79 19,900 0.88 2.77
75/57 27,900 1.00 1.92 26,200 1.00 2.25 24,900 1.00 2.50 22,500 1.00 2.76 20,000 1.00 2.73
85/72 41,800 0.61 2.39 39,400 0.63 2.82 37,500 0.65 3.15 35,700 0.68 3.50 33,100 0.70 3.49
80/67 39,400 0.68 2.37 37,500 0.71 2.80 34,600 0.74 3.14 32,000 0.76 3.47 29,500 0.80 3.43
75/63 37,100 0.72 2.36 33,900 0.75 2.79 31,500 0.77 3.12 29,400 0.82 3.45 26,200 0.86 3.42
75/57 34,300 1.00 2.32 32,300 1.00 2.75 30,800 1.00 3.08 28,900 1.00 3.40 26,100 1.00 3.36
85/72 46,300 0.64 2.69 44,600 0.66 3.22 43,200 0.68 3.64 40,600 0.70 4.06 37,800 0.72 4.10
80/67 44,000 0.71 2.68 43,200 0.74 3.18 40,000 0.76 3.63 38,000 0.78 3.98 34,000 0.81 4.03
75/63 42,100 0.74 2.67 39,200 0.77 3.17 36,900 0.79 3.56 33,800 0.83 3.96 30,600 0.87 3.98
75/57 38,300 1.00 2.63 38,800 1.00 3.15 35,600 1.00 3.56 33,100 1.00 3.94 30,400 1.00 3.95
85/72 54,400 0.65 3.10 52,100 0.66 3.72 50,200 0.67 4.19 47,200 0.69 4.66 43,500 0.71 4.71
80/67 51,900 0.71 3.08 49,500 0.73 3.64 46,000 0.76 4.18 43,500 0.78 4.55 38,400 0.80 4.65
75/63 49,900 0.73 3.06 45,600 0.76 3.64 42,300 0.78 4.09 38,700 0.82 4.55 34,300 0.85 4.60
75/57 45,200 1.00 3.02 42,800 1.00 3.63 40,900 1.00 4.10 37,900 1.00 4.53 34,200 1.00 4.56
85/72 68,500 0.60 3.87 64,500 0.62 4.61 61,300 0.63 5.17 57,500 0.65 5.76 52,300 0.66 5.75
80/67 64,800 0.66 3.83 60,800 0.68 4.49 56,500 0.70 5.09 53,000 0.72 5.62 45,300 0.77 5.61
75/63 60,900 0.69 3.81 54,500 0.72 4.50 49,600 0.75 5.03 45800 0.78 5.56 40,500 0.81 5.52
75/57 56,400 1.00 3.75 52,700 1.00 4.45 49,800 1.00 4.99 45,500 1.00 5.53 40,300 1.00 5.50
RHP13A24P
RHP13A30P
RHP13A36P
RHP13A42P
RHP13A48P
RHP13A60P
- Page 4 -
RHP13
Package Heat Pump
13
Heat Strip Electric
Minimum
Circuit
Ampacity
1
Maximum
Fuse / HACR
Minimum
Maximum
Fuse / HACR
Brkr.
Unit
Supply
Single Phase
Heater
Heater
kW
Circuit
Ampacity
2
Model No.
Model
Brkr. 2
1
2
240
208
240
208
240
208
240
208
240
208
240
208
240
208
240
208
240
208
5.0
3.7
7.0
5..3
10.0
7.5
15.0
11.3
5.0
31.2
27.8
41.7
36.8
57.3
50.3
57.3
50.3
33.3
29.9
43.8
38.9
59.4
52.4
59.4
52.4
59.4
52.4
35
30
50
40
60
60
60
60
35
30
50
40
60
60
60
60
60
60
----
----
----
----
----
----
26
22.5
----
----
----
----
----
----
26
---
---
---
---
---
---
30
25
---
---
---
---
---
---
30
25
60
50
AHSA05A
AHSA07A
AHSA010A
AHSA015A
AHSA05A
AHSA07A
RHP13A24P
RHP13A30P
RHP13A36P
3.7
7.0
5..3
10.0
7.5
15.0
11.3
20.0
15.0
RHP13A42P
RHP13A48P AHSA010A
RHP13A60P
AHSA015A
22.5
52.1
45.1
AHSA20A
Accessories
Field Provided 1"
Filter Dimensions
Description
5 kW Electric Heater
7 kW Electric Heater
10 kW Electric Heater
15 kW Electric Heater
20 kW Electric Heater
Roof Curb
Where Used
Kit Number
AHSA05A-1
AHSA07A-1
AHSA10A-1
AHSA15A-1
AHSA20A-1
ACURB161-1
ACURB163-1
ADMPR145-1
ADMPR166-1
ADMPR146-1
ADMPR167-1
AECON825-1
AECON826-1
AECON827-1
AECON828-1
24" width
28" height
All Models
All Models
All Models
All Models
42, 48 & 60
24, 30 & 36
42, 48 & 60
24, 30, 36
42, 48, 60
24, 30, 36
42, 48, 60
24, 30, 36
42, 48, 60
24, 30, 36
42, 48, 60
Small Base
Large Base
2, 2.5, 3 Ton
3.5, 4, 5 Ton
30" width
30" height
Sound Ratings
Roof Curb
Sound
dBA
Model No.
Manual Fresh Air Damper
Manual Fresh Air Damper
Motorized Fresh Air Damper
Motorized Fresh Air Damper
Downflow Economizer
Downflow Economizer
Horizontal Economizer
Horizontal Economizer
- Page 5 -
RPHP13A24P
RPHP13A30P
RPHP13A36P
RPHP13A42P
RPHP13A48P
RPHP13A60P
77
77
77
80
80
80
RHP13
Package Heat Pump
13
Dimensions (in.)
Model No.
RHP13-24
RHP13-30
RHP13-36
RHP13-42
RHP13-48
RHP13-60
A
B
C
D
E
F
32-1/2 46-1/2 46-1/2 45-5/8 45-5/8 17-1/2
34-1/2 55-1/2 50-1/2 54-5/8 49-5/8 21-1/2
Model No.
G
H
J
K
L
RHP13-24
RHP13-30
RHP13-36
RHP13-42
RHP13-48
RHP13-60
11-1/2 5-1/2
1-5/8
4
4
12
5-1/2
1-5/8
6-1/4
5-5/8
Model No.
M
N
P
Q
R
RHP13-24
RHP13-30
RHP13-36
RHP13-42
RHP13-48
RHP13-60
1-3/4 15-5/8 27-3/4 24-7/8 9-3/4
2-3/8 17-1/8 29-3/4 26-7/8 15-1/2
Elec. Heat
Power Entry
All specifications and illustrations
subject to change without notice
and without incurring obligations.
1-800-448-5872
Form No. DRHP13-100 (06/11)
©2011 Allied Air Enterprises Inc., a Lennox International Inc. Company
Printed in the U.S.A.
- Page 6 -
|